Model
|
1400W80
|
|
System Rated Voltage
|
24V(18V-32VDC)
|
|
Solar Module Voc
|
55.2V
|
|
Solar Module Vmp
|
>Vbat+1V
|
|
Solar Module Imp
|
20A
|
|
Solar Module Workable Power
|
0W~600W
|
|
Wind Turbine Rated Voltage
|
24VAC(41.6VDC)
|
|
Wind Turbine Rated Current
|
26.7A
|
|
Wind Turbine Workable Power
|
0W~800W
|
|
DC Load Out Power
|
0W~700W (Per one-way)
|
|
DC Load Rated Voltage
|
24VDC
|
|
DC Load Current Max
|
30A(15A*2)
|
|
Battery Max Charging
|
46.7A
|
|
Over Discharge Voltage
|
21.6V
|
|
Over Discharge Return
|
26.2V
|
|
Over Charge Voltage
|
31.0V
|
|
Over Charge Return
|
30.0V
|
|
Increase Charge
|
28.8V
|
|
Floating Charge
|
27.6V
|
|
Wind Breaking Voltage
|
51.2V
|
|
No-load Current
|
≦0.1A
|
|
Voltage drop (DC)
|
≦0.5V
|
|
Protection Grade
|
IP30
|
Perfect Protection
Solar Reversed Charging protection,Battery open circuit protection、battery anti-reverse connection protection protection、Over current and over voltage auto brake protection、Over load protection,etc.